A-series Heatless and Regeneration Adsorption Gas Dryer
Designing Feature
:
The Technical Parameter
HAD |
0007 |
0012 |
0024 |
0034 |
0060 |
0120 |
0170 |
0240 |
0320 |
0450 |
0550 |
0650 |
|
The
amount of disposing (nm3/min) |
0.7 |
1.2 |
2.4 |
3.4 |
6.0 |
12 |
17 |
24 |
32 |
45 |
55 |
65 |
|
Rated
temperature of inlet gas |
<40
deg. C |
||||||||||||
Rated
working pressure |
0.7
MPa |
||||||||||||
Pressure |
<0.02
Mpa |
||||||||||||
Dew
point of pressure |
-40
deg. C |
||||||||||||
Mode
of regenerating |
No
heat and regenerating |
||||||||||||
Mode
of controlling |
All electrically and programmatically |
||||||||||||
Gas
consumption |
About 15% |
||||||||||||
Adsorbent |
CaCl2 |
||||||||||||
Oil
Amount |
>0.1mg/m3 |
||||||||||||
Exterior Dimension |
L |
650 |
750 |
750 |
900 |
1100 |
1300 |
1300 |
1600 |
1950 |
2100 |
2100 |
2100 |
W |
400 |
350 |
350 |
600 |
600 |
800 |
800 |
800 |
850 |
850 |
1000 |
1000 |
|
H |
1000 |
1460 |
1460 |
1700 |
2020 |
2300 |
2400 |
2600 |
3020 |
3060 |
3060 |
3100 |
|
Dimension
of connecting Pipe |
G0.2” |
G1” |
G1” |
G1.5” |
G2” |
DN70 |
DN70 |
DN80 |
DN100 |
DN100 |
DN100 |
DN100 |
|
Weight(Kg) |
230 |
250 |
310 |
450 |
680 |
850 |
1420 |
1660 |
2150 |
3380 |
3510 |
||
Mode
of Installation Indoors |
concrete,
the environmental temperature: above 0 deg. C |
||||||||||||
Copyright 2002 By DY Refrigeration, All Rights Reserved